46 | About Your System
Byte
Field
Value
Description
8 Event Data1 AXh 01h: OEM BIOS recovery
Event
9 Event Data2 XXh 01h:Start Recovery
02h:Recovery Success
03h:Load Image Fail
04h:Signed Fail
10 Event Data3 FFh FFh: Not Present
ME Fail Event
Byte
Field
Value
Description
1 NetFunLun 10h
2 Platform Event Command 02h
3 Generator ID 01h Generated by BIOS
4 Event Message
Format Version
04h Event Message Format
Revision. 04h for this
specification.
5 Sensor Type 12h System Event
6 Sensor Number 8Ah ME fail (depend on platform)
7 Event Direction
Event Type
6Fh Bit 7: 0 = Assert Event
Bit 6: 0 = Event Type Code
8 Event Data1 AXh 01h: OEM ME fail Event
9 Event Data2 XXh 01h:ME fail
10 Event Data3 FFh FFh: Not Present
SEL Generator ID
Generator ID
BIOS
0x0001
BMC
0x0020
ME
0x002C
Windows 2008
0x0137