Troubleshooting Your System | 309
3 Ensure that the appropriate drivers are installed and the protocols are
bound. See the NICs documentation.
4 Enter the System Setup program and confirm that the NIC ports are
enabled. See Using the System Setup Programon page 68.
5 Ensure that the NICs, hubs, and switches on the network are all set to
the same data transmission speed. See the documentation for each
network device.
6 Ensure that all network cables are of the proper type and do not exceed
the maximum length.
If all troubleshooting fails, see Getting Helpon page 339.
Troubleshooting a Wet System
CAUTION: Many repairs may only be done by a certified service technician. You
should only perform troubleshooting and simple repairs as authorized in your
product documentation, or as directed by the online or telephone service and
support team. Damage due to servicing that is not authorized by Dell is not
covered by your warranty. Read and follow the safety instructions that came with
the product.
1 Turn off the system and attached peripherals, and disconnect the
system from the electrical outlet.
2 Open the system. See Opening the System on page 246.
3 Disassemble components from the system. See Installing System
Componentson page 151.
Hard drives
SAS backplane
Expansion-card
Power supplies
Fans
Processors and heat sinks
Memory modules
4 Let the system dry thoroughly for at least 24 hours.