74 | Using the System Setup Program
DHCP Enabled: Disabled or Enabled (Enabled if DHCP server
support)
IP Address: 192.168.001.003
Subnet Mask: 255.255.255.000
Gateway Address: 000.000.000.000
To do this, see “Set BMC LAN Configuration” on page 113. Note that the
host and client need to have the same network section.
To enable SOL feature in the mode of Shared-NIC, perform the following
steps:
1 Connect the LAN cable to NIC connector 1. For location of NIC
connector 1 on the back panel, see Figure 1-14 item 5.
2 Enter the server BIOS setup screen.
3 Enter Set BMC LAN Configuration screen and verify the following
settings:
Remote Access: enabled
Serial port number: COM2
Serial Port Mode: 115200 8, n, 1
Flow Control: None
Redirection After BIOS POST: Always
Terminal Type: ANSI
To do this, see “Remote Access Configuration” on page 114. Note that the
last four options need to sync with the host and client.
4 Enter LAN Configuration screen and verify the following settings:
BMC LAN Port Configuration: Shared-NIC
DHCP Enabled: Disabled or Enabled (Enabled if DHCP server
support)
IP Address: 192.168.001.003
Subnet Mask: 255.255.255.000
Gateway Address: 000.000.000.000
To do this, see “Set BMC LAN Configuration” on page 113
. Note that the
host and client need to have the same network section.