M.2 SSD module
Removing the M.2 NVMe SSD module
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
3. Remove the BOSS-N1 module.
Steps
1. Using the Phillips #1 screwdriver, remove the M3 x 0.5 x 4.5 mm screw securing the M.2 NVMe SSD module to the BOSS-N1
card.
2. Pull the M.2 NVMe SSD module to disconnect from the BOSS-N1 card connector.
NOTE: The numbers on the image do not depict the exact steps. The numbers are for representation of sequence.
Figure 185. Removing the M.2 NVMe SSD module
Next steps
1. Replace the M.2 NVMe SSD module.
Installing the M.2 NVMe SSD module
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
3. Remove the BOSS-N1 module
Steps
1. Align the M.2 NVMe SSD module at an angle with the BOSS-N1 card connector.
2. Insert the M.2 NVMe SSD module until it is firmly seated in the BOSS-N1 card connector.
3. Using the Phillips #1 screwdriver, secure the M.2 NVMe SSD module on the BOSS-N1 card with the M3 x 0.5 x 4.5 mm
screw.