System diagnostics and indicator codes
The diagnostic indicators on the system front panel display system status during system startup.
Topics:
Status LED indicators
System health and system ID indicator codes
iDRAC Quick Sync 2 indicator codes
iDRAC Direct LED indicator codes
LCD panel
NIC indicator codes
Power supply unit indicator codes
Drive indicator codes
EDSFF E3.S drive led codes
Status LED indicators
NOTE: The indicators display solid amber if any error occurs.
Figure 232. Status LED indicators
Table 121. Status LED indicators and descriptions
Icon Description Condition Corrective action
Drive indicator
The indicator turns solid amber if
there is a drive error.
Check the System Event Log to determine if the
drive has an error.
Run the appropriate Online Diagnostics test.
Restart the system and run embedded
diagnostics (ePSA).
If the drives are configured in a RAID array,
restart the system, and enter the host adapter
configuration utility program.
Temperature
indicator
The indicator turns solid amber if
the system experiences a thermal
error (for example, the ambient
Ensure that none of the following conditions exist:
A cooling fan has been removed or has failed.
System cover, air shrouds, or back filler bracket
has been removed.
10
254 System diagnostics and indicator codes

Table of Contents