● Wrist grounding strap connected to the ground
● ESD mat
● Needle-nose pliers to disconnect cables and connectors in hard-to-reach locations
You need the following tools to assemble the cables for a DC power supply unit:
● AMP 90871-1 hand-crimping tool or equivalent
● Tyco Electronics 58433-3 or equivalent
● Wire-stripper pliers to remove insulation from size 10 AWG solid or stranded, insulated copper wire
NOTE: Use alpha wire part number 3080 or equivalent (65/30 stranding).
NOTE: For information about DC PSU cabling instructions, go to https://www.dell.com/poweredgemanuals > Rack
Servers > PowerEdge R660 > Select This Product > Documentation > Manuals and Documents > Cabling
instructions for – 48 – 60 V DC power supply.
Cable routing
Figure 29. Configuration 0-: 8 x 2.5 inch (SAS4/SATA) (fPERC12)
NOTE:
Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse
sequential order.
Table 71. 8 x 2.5 inch (SAS4/SATA) (fPERC12)
Order From To
1 SIG_PWR_1 (system board power
connector)
BP_PWR_1 (backplane power connector)
2 SL3_CPU1_PA2 (signal connector on
system board)
CTRL_DST_PA1 (fPERC input connector)
3 CTRL_SRC_SA1 (fPERC controller
connector)
BP_DST_SA1 (backplane signal connector) and BP_DST_SB1
(backplane signal connector)
4 BP_PWR_CTRL (backplane power
connector)
FPERC_GF
74 Installing and removing system components