Table 5-4. Factory Default Settings (continued)
Restored Item Default Setting* Comments
Library Mode Random
Library Name (Blank)
Host Name (Depends on MAC Address)
Logs & Traces Error Log Mode Continuous
Path Failover Key No change License Key is protected, if
previously entered.
OCP Access PIN Disabled
Note: The initial Factory Default
setting is disabled. If the OCP Access
PIN setting is changed, executing
"Restore Defaults" will not change the
setting.
If OCP Access PIN has been enabled
the default PIN is "1234".
SSL for Web Disabled
Drives
Power Power On (All drives)
Drive 1 SCSI-ID 4 SCSI Drives
Drive 2 SCSI-ID 5 SCSI Drives
Drive 3 SCSI-ID 6 SCSI Drives
Drive 4 SCSI-ID 8 SCSI Drives
Drive 1 Loop-ID 4 FC Drives Arbitrated Loop
Drive 2 Loop-ID 5 FC Drives Arbitrated Loop
Control Path Drive Drive 1 only
Partitions None
Reserved Slots 2U:24, 4U:48
IPv6 Stateless Autoconfig Enabled
Note: * = all settings at library firmware level 4.xx and greater
In some cases, (such as Library Mode), the entry of one option precludes any other
options from being selected. In such cases, the details of the non-applicable options
are not shown.
Configure: Set Date and Time
Use this menu item to set the current date and time in your library.
Configure: Path Failover
Use this menu item to enter the Path Failover Feature Activation key (Supported
on 4U library only for library firmware levels at or below 8.xx. Supported on both
Configure
Set Date
and Time
a77ug046
Figure 5-20. Configure: Set Date and Time menu
Chapter 5. Operations 5-29