Removing a Tape Drive Sled
1. IT IS IMPORTANT TO PRESERVE A DRIVE DUMP FOR ANALYSIS IF ALL OF
THE FOLLOWING CONDITIONS EXIST:
v Library Error LED is ON.
v Operator Control Panel is displaying a drive error message.
v Web User Interface System Status screen is indicating that a drive has failed.
IF NONE OF THE CONDITIONS LISTED ABOVE EXIST, PROCEED TO THE
NEXT STEP.
2. Power OFF the library before removing and/or installing a SCSI drive sled.
Fibre Channel and SAS drive sleds are hot pluggable and may be removed and
installed while the library is powered ON.
3. If necessary, unload the tape cartridge from the drive to be removed.
v Using the Operator Control Panel: Control Move Cartridges
v Using the Web User Interface: Manage Library Move Media
4. Remove the host interface cable (1, 2,or4 in Figure 10-6 on page 10-5)
and terminator (3 for SCSI drive sled only).
a77ug202
1
Figure 10-5. Library drive sled with ESD springs [1] (SAS sled shown)
10-4 Dell PowerVault TL2000 Tape Library and TL4000 Tape Library User's Guide

Table of Contents

Other manuals for Dell PowerVault TL2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerVault TL2000 and is the answer not in the manual?

Dell PowerVault TL2000 Specifications

General IconGeneral
Number of Drives1 or 2
Number of Slots24
TypeTape Library
Drive TypesLTO-4, LTO-5, LTO-6
InterfaceSAS, Fibre Channel
Dimensions8.68 in (22.05 cm) x 19.0 in (48.26 cm) x 30.0 in (76.2 cm)
Tape Drive CompatibilityLTO-4, LTO-5, LTO-6
Power SupplyRedundant power supplies optional
Operating Temperature50°F to 95°F (10°C to 35°C)
Non-operating Temperature-40°F to 140°F (-40°C to 60°C)

Related product manuals