Table B-1. TapeAlert Flags Supported by the Ultrium Tape Drive (continued)
Flag
Number Flag Description Action Required
55 Loading Failure When loading a tape into a drive, a
hardware malfunction can prevent the
tape from being loaded into the drive,
or the tape may actually get stuck in
the drive.
Take this action if the tape cartridge
will not load in the drive:
1. Remove the tape cartridge from
the library and inspect it for
damage. If damaged, discard it.
2. Try another cartridge in that
tape drive. If it still fails, replace
the drive sled. See
“Removing/Installing/Adding a
Tape Drive Sled” on page 10-3.
Take this action if the tape is stuck
in the drive:
1. Attempt to unload the tape from
the drive using the host backup
application that is currently
using the drive, or using the
remote or local UI.
2. If the cartridge will not unload,
contact technical support.
56 Unload Failure When attempting to unload a tape
cartridge, a drive hardware
malfunction can prevent the tape from
being ejected. The tape may actually
be stuck in the drive.
1. Unload the cartridge from the
drive using the Operator Control
Panel (Control Move
Cartridge) or the Web User
Interface (Manage Library
Move Media).
2. Cycle drive power using the
Operator Control Panel (Service
Service Drive Power)orthe
Web User Interface (Configure
Library Drives).
3. Try unloading the cartridge from
the drive again using the
Operator Control Panel (Control
Move Cartridge) or the Web
User Interface (Manage Library
Move Media).
4. If the cartridge will not unload
from the drive, contact technical
support.
59 WORM Medium
integrity check failed
Set when the drive determines that
the data on tape is suspect from a
WORM point of view.
1. Copy the data to another
WORM tape cartridge.
2. Discard the old WORM tape.
60 WORM Medium
Overwrite attempted
Set when the drive rejects a write
operation because the rules for
allowing WORM writes have not been
met. Data can only be appended to
WORM media. Overwrites to WORM
media are not allowed.
Append the information on a
WORM tape cartridge or write the
data to a non-WORM cartridge.
Appendix B. TapeAlert Flags B-5

Table of Contents

Other manuals for Dell PowerVault TL2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerVault TL2000 and is the answer not in the manual?

Dell PowerVault TL2000 Specifications

General IconGeneral
Number of Drives1 or 2
Number of Slots24
TypeTape Library
Drive TypesLTO-4, LTO-5, LTO-6
InterfaceSAS, Fibre Channel
Dimensions8.68 in (22.05 cm) x 19.0 in (48.26 cm) x 30.0 in (76.2 cm)
Tape Drive CompatibilityLTO-4, LTO-5, LTO-6
Power SupplyRedundant power supplies optional
Operating Temperature50°F to 95°F (10°C to 35°C)
Non-operating Temperature-40°F to 140°F (-40°C to 60°C)