190
Important
Receiving the BHT-BASIC data files (specifying the field information)
A data file received in MTP is a file that has no f
iled information and so cannot be used for the
BHT-BASIC applications.
To receive this file as a data file having field information, convert it in the
following procedure.
1. Create a MTP field information file “MTPFLD.INI” carrying the file name and field i
on the data file.
2. Save the MTPFLD.INI file in the BHT (downloadable via MTP).
3. Download the data file via MTP.
The data file is converted to a data file that has field
information according to the description of MTPFLD.INI.
MTPFLD.INI file format
This is a data file consisting of a single filed of 256 characters long.
Write the file name and field information in the field using the “xxx:yyy”* format.
* “xxx” indicates the file name and “yyy” the field information.
MASTER.DAT:10,14,20,4,8,128
TENPO.TXT:8,8,8
URIAGE.DAT:64