BHT-1500B series
4.5.5 Copying Files between 2 BHT Units
Copy all files (excluding font files), setting data, and the date and timestored in the BHT user area to
another BHT.
Use the following procedure to copy files between 2 BHT units.
1. Set COMMUNICATION PROTOCOL OPTION FIELD SPACE(space at the end of the
field) to Ignoreat both BHT units.
The default setting is Ignore”.
Refer to “4.5.6 [5] Setting the communication environmentwhen changing the interface.
2. Ensure that the BHT infrared communication ports are facing one another.
3. Select “2: DOWNLOAD” > 2: HT<-->HT COPY” at the SYSTEM MENU of the BHT that is
downloading to wait for downloading.
Refer to 4.5.3 Downloading Files (DOWNLOAD Menu)for details.
When copying only the system parameter file, use the SYSTEM PARAMETER transfer menu. Refer to
4.5.15 Downloading/Uploading the BHT System Parameter File (SYSTEM PARAMETER Menu) for
details.
4. Select “3: UPLOAD” > “3: HT<-->HT COPY” at the SYSTEM MENU of the BHT that is uploading
to await uploading.
Refer to the 4.5.4 Uploading Files (UPLOAD Menu)for details.
When copying only the system parameter file, use the SYSTEM PARAMETER transfer menu. Refer to
4.5.15 Downloading/Uploading the BHT System Parameter File (SYSTEM PARAMETER Menu) for
details.
5. Preparation at both BHT units is now complete and file copying will be commenced.