System administration Schedule system maintenance tasks
Digi Connect IT® 16/48 User Guide
614
n If the duration length is set to any value other than to 0 or 24 hours, the
maintenance tasks will run at a random time during the time allotted for the
duration window.
n If the duration length is set to one or more hours, the minutes field in the start time
is ignored and the duration window will begin at the beginning of the specified hour.
b. Configure the duration length (the amount of time that the maintenance tasks will be run).
If 0 is used, all scheduled tasks will begin at the start time, defined in the previous step.
(config)> system schedule maintenance length num
(config)>
where num is any whole number between 0 and 24.
c. Configure the frequency that the maintenance tasks should be run:
(config)> system schedule maintenance frequency value
(config)>
where value is either daily or weekly. Daily is the default.
4. Configure the device to look for any updated modem firmware during the maintenance
window. If updated firmware is found, it will then be installed. The device will look for updated
firmware both on the local device and over the network, using either a WAN or cellular
connection.
system schedule maintenance modem_fw_update value
(config)>
where value is either true or false. yes or no, and 1 or 0 are also allowed.
5. (Optional) Configure automated checking for device firmware updates:
a. Device firmware update check is enabled by default. This enables to automated checking
for device firmware updates. To disable:
(config)> system schedule maintenance firmware_update_check device false
(config)>
b. Set how often automated checking for device firmware should take place:
(config)> system schedule maintenance frequency value
(config)>
where value is either daily, weekly, or monthly. daily is the default.
6. (Optional) Allow scheduled scripts to handle SMS messages:
(config)> system schedule sms_script_handling true
(config)>
7. (Optional) Schedule custom scripts:
a. Add a script:
(config)> add system schedule script end
(config system schedule script 0)>