Virtual Private Networks (VPN) OpenVPN
IX30 User Guide
422
Format:
/network/interface/defaultip
/network/interface/defaultlinklocal
/network/interface/eth1
/network/interface/eth2
/network/interface/loopback
Current value:
(config vpn openvpn client openvpn_client1 surelink
target 0)> other_interface
ii. Set the interface. For example:
(config vpn openvpn client openvpn_client1 surelink
target 0)> other_interface /network/interface/eth1
(config vpn openvpn client openvpn_client1 surelink
target 0)>
o
Set the alternate interface's IP version. This allows you to determine the
alternate interface's status for a particular IP version.
(config vpn openvpn client openvpn_client1 surelink target
0)> other_ip_version value
(config vpn openvpn client openvpn_client1 surelink target
0)>
where value is one of: any, both, ipv4, or ipv6.
o
Set the expected status of the alternate interface:
(config vpn openvpn client openvpn_client1 surelink target
0)> other_status value
(config vpn openvpn client openvpn_client1 surelink target
0)>
where value is either up or down. For example, if other_status is set to
down, but the alternate interface is determined to be up, then this test will
fail.
12. Save the configuration and apply the change:
(config vpn openvpn client openvpn_client1 connection_monitor target 0)>
save
Configuration saved.
>
13. Type exit to exit the Admin CLI.
Depending on your device configuration, you may be presented with an Access selection
menu. Type quit to disconnect from the device.
See Show Surelink status and statistics for information about showing Surelink status for OpenVPN
clients.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Digi IX30 and is the answer not in the manual?

Digi IX30 Specifications

General IconGeneral
CategoryNetwork Router
ModelIX30
Serial Ports1 x RS-232
Operating Temperature-40° C to 70° C
ConnectivityEthernet
USB Ports1 x USB 2.0
Cellular Interface4G LTE Cat 4
Wi-Fi802.11 a/b/g/n/ac
SIM Slots1
ProcessorARM Cortex-A9
Memory1 GB RAM

Related product manuals