Applications Develop Python applications
IX30 User Guide
654
>>> from digidevice import location
>>>
4. Use the help command with location:
>>> help(location)
Help on module digidevice.location in digidevice:
NAME
digidevice.location - digidevice.location - API for accessing location
data
...
5. Use Ctrl-D to exit the Python session. You can also exit the session using exit() or quit().
Use Python to set the maintenance window
The maintenance Python module allows you to set the service state of a device. When the module
sets the device to out of service, this can be used as trigger to begin maintenance activity. See
Schedule system maintenance tasks for more details.
1. Select a device in Remote Manager that is configured to allow shell access to the admin user,
and click Actions > Open Console. Alternatively, log into the IX30 local command line as a user
with shell access.
Depending on your device configuration, you may be presented with an Access selection
menu. Type shell to access the device shell.
2. At the shell prompt, use the python command with no parameters to enter an interactive
Python session:
# python
Python 3.10.1 (default, May 9 2021, 22:49:59)
[GCC 8.3.0] on linux
Type "help", "copyright", "credits" or "license" for more information.
>>>
3. Import the maintenance module:
>>> from digidevice import maintenance
>>>
4. To determine the current service state of the device:
>>> maintenance.state()
'IN_SERVICE'
>>>
5. To set the device to out of service:
>>> maintenance.out_of_service()
>>> maintenance.state()
'OUT_OF_SERVICE'
>>>

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Digi IX30 and is the answer not in the manual?

Digi IX30 Specifications

General IconGeneral
CategoryNetwork Router
ModelIX30
Serial Ports1 x RS-232
Operating Temperature-40° C to 70° C
ConnectivityEthernet
USB Ports1 x USB 2.0
Cellular Interface4G LTE Cat 4
Wi-Fi802.11 a/b/g/n/ac
SIM Slots1
ProcessorARM Cortex-A9
Memory1 GB RAM

Related product manuals