4. Set the protocol version:
(config)> monitoring netflow protocol version
(config)>
where version is one of:
n
v5—NetFlow v5 supports IPv4 only.
n
v9—NetFlow v9 supports IPv4 and IPv6.
n
v10—NetFlow v10 (IPFIX) supports both IPv4 and IPv6 and includes IP Flow Information
Export (IPFIX).
The default is v10.
1. Enable flow sampling by selecting a sampling technique. Flow sampling can reduce flow
processing and transmission overhead by providing a representative subset of all flows.
(config)> monitoring netflow sampler type
(config)>
where type is one of:
n
none—No flow sampling method is used. Each flow is accounted.
n
deterministic—Selects every nth flow, where n is the value of the flow sample
population.
n
random—Randomly selects one out of every n flows, where n is the value of the flow
sample population.
n
hash—Randomly selects one out of every n flows using the hash of the flow key, where
n is the value of the flow sample population.
5. If you are using a flow sampler, set the number of flows for the sampler:
(config)> monitoring netflow sampler_population value
(config)>
where value is any number between 2 and 16383. The default is 100.
6. Set the number of seconds that a flow can be inactive before sent to a collector:
(config)> monitoring netflow inactive_timeout value
(config)>
where value is any is any number between 1 and 15. The default is 15.
7. Set the number of seconds that a flow can be active before sent to a collector:
(config)> monitoring netflow active_timeout value
(config)>
where value is any is any number between 1 and 1800. The default is 1800.
8. Set the maximum number of flows to probe simultaneously:
(config)> monitoring netflow max_flows value
(config)>
where value is any is any number between 0 and 2000000. The default is 2000000.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Digi IX30 and is the answer not in the manual?

Digi IX30 Specifications

General IconGeneral
CategoryNetwork Router
ModelIX30
Serial Ports1 x RS-232
Operating Temperature-40° C to 70° C
ConnectivityEthernet
USB Ports1 x USB 2.0
Cellular Interface4G LTE Cat 4
Wi-Fi802.11 a/b/g/n/ac
SIM Slots1
ProcessorARM Cortex-A9
Memory1 GB RAM

Related product manuals