Diagnostics View system and event logs
IX30 User Guide
922
5. Click to download the system log.
Command line
1. Select the device in Remote Manager and click Actions > Open Console, or log into the IX30
local command line as a user with full Admin access rights.
Depending on your device configuration, you may be presented with an Access selection
menu. Type admin to access the Admin CLI.
2. Use the show log command at the Admin CLIprompt:
> show log
Timestamp Message
-------------- ---------------------------------------------------------
----
Nov 26 21:54:34 IX30 netifd: Interface 'interface_wan' is setting up now
Nov 26 21:54:35 IX30 firewalld[621]: reloading status
...
>
3. (Optional) Use the show log number num command to limit the number of lines that are
displayed. For example, to limit the log to the most recent ten lines:
> show log number 10
Timestamp Message
-------------- ---------------------------------------------------------
----
Nov 26 21:54:34 IX30 netifd: Interface 'interface_wan' is setting up now
Nov 26 21:54:35 IX30 firewalld[621]: reloading status
...
>
4. (Optional) Use the show log filter value command to limit the number of lines that are
displayed. Allowed values are critical, warning, info, and debug. For example, to limit the
event list to only info messages:
> show log filter info
Timestamp Type Category Message
---------------- ------- --------- --------------------------------------
-----
Nov 26 22:01:26 info user
name=admin~service=cli~state=opened~remote=192.168.1.2
Nov 26 22:01:25 info user
name=admin~service=cli~state=closed~remote=192.168.1.2

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Digi IX30 and is the answer not in the manual?

Digi IX30 Specifications

General IconGeneral
CategoryNetwork Router
ModelIX30
Serial Ports1 x RS-232
Operating Temperature-40° C to 70° C
ConnectivityEthernet
USB Ports1 x USB 2.0
Cellular Interface4G LTE Cat 4
Wi-Fi802.11 a/b/g/n/ac
SIM Slots1
ProcessorARM Cortex-A9
Memory1 GB RAM

Related product manuals