SECTION 6 Field Replaceable Parts
0855855eng 6/08 6–19
CAUTION: Hot Surfaces. The filter can be hot. To prevent injury
from burns, use a protective glove or pliers when
removing the filter.
Figure 6–17
8.4 Replacement
1. Install the two new O-rings on the new filter. Place the new filter
into the opening, and gently push the filter in by pushing in the
center of the filter top.
2. Install the two screws previously removed.
8.5 Final Steps
When paragraphs 7.2 through 7.4 are complete:
1. Install the front cover.
NOTE: The ground wire may need to be connected to the print
station first.
2. Connect the power cable and power on the Model 5200/5400.
3. The pump count must be reset from the Machine Setup menu.
Note that Level 3 access is required.
From the Top Level menu, press Main Menu (F4).
Press Machine Setup (F4).
Select Initialization.
Select Reset Pump Count and follow the prompts.