13.6.3 Aligning the flap turning device as to the feeding device and to the sewing level
The feeding device of working method B must transfer the flap
precisely into the flap clamp 1 of the feeding clamp.
Pick-up folder, folder, feeding clamps and sewing equipment must be
adjusted in such a way that a good sewing result is already achieved.
The flap turning device cannot compensate errors of the feeding
device of working method B.
Mounting the flap turning device
Screw on the flap turning device in the center of the slotted holes
of the folding station plate by means of the screws 2, 3 and 4.
Make sure that the thrust bolts 5, 6 and 7 have no pretension.
Aligning the flap clamp of the flap turning device as to the
measuring line 125
Loosen the screws 1 and 2.
Align the stationary and the movable flap clamp parallel to the
measuring line 125.
Tighten the screws 1 and 2.
3
121
1
432
5
6
7
281