15. Positioning device for working method D
15.1 General notes
The breast welt lying on the preparation table is seized by the
positioning device and positioned on the still inaccurately aligned
jacket front.
This allows exact matching as per pattern and subsequent suction of
the jacket front by the vacuum.
After the feeding clamps have lowered on the jacket front, the breast
welt is lifted again, turned and fed to the flap clamp.
The maximum sewing length of breast welt pockets is 145 mm.
15.2 Aligning the folder
Caution: Danger of injury !
Switch off the main switch.
Adjust the positioning device only with the main switch turned off.
Carry out adjustments with utmost caution when the sewing
machine is running.
Standard
The folder has to be aligned exactly as described for the working
method B, D and F in c hapter 12.
3
135