15.3 Aligning the positioning device
Caution: Danger of injury !
Switch off the main switch.
Check and adjust the positioning device only with the main switch
turned off.
Carry out adjustments with utmost caution when the sewing
machine is running.
Correction
The positioning device 1 is fastened to the mounting plate 5.
Align the mounting plate 5.
Description: see chapter 12.6 Pick-up folder.
Put the positioning device 1 into the mounting plate 5 and align in
parallel position to the measuring line 7. Tighten screw 3.
Loosen screws 4 and 6.
Align the left edge of clamp 2 in parallel position to the
measuring line 7.
Tighten screws 4 and 6.
136