Troubleshooting
116 Operating Instructions 967 - 02.0 - 11/2016
7222 DA stepper card 2 boot
error
Check connection cables
Perform software update
Replace DACextension box
7223 Checksum error occurred
while updating DA stepper
card 2
Check connection cables
Perform software update
Replace DACextension box
7801 Software version error
(DACclassic only; only the
functions of the DACbasic
will remain available)
Perform software update
Replace the control
7802 Software update error
(DACclassic only; only the
functions of the DACbasic
will remain available)
Perform software update
again
Replace the control
7803 Communication error
(DACclassic only; only the
functions of the DACbasic
will remain available)
Restart the control
Perform software update
Replace the control
Code Possible cause Remedial action