Maintenance
Operating Instructions 967 - 02.0 - 11/2016 79
Fig. 40: Cleaning
Points that need to be cleaned particularly thoroughly:
• Thread-pulling knife (3)
• Area between throat plate and feed dog (2)
• Hook (4)
• Thread cutter (1)
• Area around the needle (5)
To clean the machine:
1. Switch off the machine.
2. Remove the throat plate.
3. Remove any lint and thread remnants using a brush or com-
pressed air gun.
(1) - Thread cutter
(2) - Feed dog
(3) - Thread-pulling knife
(4) - Hook
(5) - Area around the needle