Parameter Possible Values Default HHP Lite Std Adv
System Options (6.5.8 System Options)
Service Scheduler No / Yes No
✓ ✓
Service Period 0 - 5100h 5000h
✓ ✓ ✓ ✓
Actuator Time-Out NOT USED
Enable 1Hz Data No/Yes No
✓
Low Power Mode
Duration
1
0 – 90 days 0
✓
Multi-function Inputs Configuration ( 6.5.9 Multi-function Inputs Configuration)
Pin 4 Function
None
Reverse Drive
Release Brake
Charger Inhibit
Profile2
Slow
Slow/Stop
Slow/Stop FWD
Slow/Stop REV
SRW
SRW (variable)
Neutral Detect
Actuator Wig-Wag
(NOTUSED)
Actuator Control
(NOTUSED)
Profile 2
✓ ✓
Pin 6 Function Slow/Stop
✓ ✓
Pin 12 Function Reverse Drive
✓ ✓
Pin 14 Function Charger Inhibit
✓ ✓
Prog/Inh Pin Function Charger Inhibit
✓ ✓
Multi-function Outputs Configuration (6.5.10 Multi-function Outputs Configuration)
Flash Code Type
Scooter
Shark
Type 3
Type 4
Scooter
✓ ✓
Pin 3 Function
None
Brake Light
Reverse Light
Beeper
Status
Power Status
Beeper
✓ ✓
Pin 11 Function Power Status
✓ ✓
Pin 10 Function
None
Status High
Status Low
Fault High
Fault Low
5V Gauge
12V Gauge
Other
Status High
✓ ✓
Key Switch Status LED No / Yes Yes
✓
1
Low power mode is only available in firmware supporting DFVN 6. Program revisions and software versions are detailed in
the table in section 6.2.1 Software version and module version.