6 Technical Data
6.9 Braking resistances
160 DC1 Variable Frequency Drive 04/16 MN04020003Z-EN www.eaton.com
Mains voltage 400 V
Supply voltage (50/60 Hz) U
LN
380 (-10 %) - 480 (+10 %) V
U
e
400 V AC, three-phase / U
2
400 V AC, three-phase
DC1-344D1NB-A20N
FS2 210 250 1.5 DX-BR210-200 210 0.2 13 16 DX-BR100-600 100 0.6 40 48
DC1-344D1FB-A20N
DC1-345D8NB-A20N FS2 200 200 2.2 DX-BR200-0K4 200 0.4 18 22 DX-BR050-720 50 0.72 33 39
DC1-345D8FB-A20N
DC1-349D5NB-A20N FS2 120 120 4 DX-BR150-0K5 150 0.5 13 15 DX-BR025-1440 25 1.44 36 43
DC1-349D5FB-A20N
DC1-34014NB-A20N FS3 100 100 5.5 DX-BR100-0K8 100 0.8 15 17 DX-BR025-1920 25 1.92 35 42
DC1-34014FB-A20N
DC1-34018NB-A20N FS3 80 80 7.5 DX-BR100-960 100 0.96 13 15 DX-BR027-2880 27 2.88 38 46
DC1-34018FB-A20N
DC1-34024NB-A20N FS3 50 50 11 DX-BR050-1440 50 1.44 13 16 DX-BR050-5K1 50 5.1 46 56
DC1-34024FB-A20N
DC1-34030NB-A20N FS4 30 30 15 DX-BR050-1920 50 1.92 13 15 DX-BR040-5K1 40 5.1 34 41
DC1-34030FB-A20N
DC1-34039NB-A20N FS4 22 22 18.5 DX-BR025-1920 25 1.92 10 12 DX-BR022-9K2 22 9.2 50 60
DC1-34039FB-A20N
DC1-34046NB-A20N FS4 22 22 22 DX-BR025-1920 25 1.92 9 10 DX-BR022-9K2 22 9.2 42 50
DC1-34046FB-A20N
Resistance values:
R
Bmin
= Minimum permissible resistance;
R
Brec
= Recommended resistance
P
max
= Rated power for low-duty and high-duty classifications
Device Type
Size
Resistance value Braking resistance (Low duty) Braking resistance (High duty)
Type Type
R
Bmin
R
Brec
P
max
R
Brec
P
max
DF t
Brems
R
Brec
P
max
DF t
Brems
kW kW % s kW % s

Table of Contents

Other manuals for Eaton PowerXL DC1

Related product manuals