Function of CI 3000
27
Version 2.09 09. April 2014
Examples (assembled with all sensors):
CI 3000 Store Computer with 2 MB of memory: 40 memory units
Number Memory units required
16 refrigeration points UA 300 / UA 300 D/L/V or
10 refrigeration points UA 300 E / UA 400 E
16 x 1,4 ~23
10 x 2,3 = 23
2 compact-refrigeration points UA 30 Rx 2 x 1 = 2 2 x 1 = 2
2 refrigeration packs VS 3010 2 x 2,5 = 5 2 x 2,5 = 5
10 wireless temperature sensors TS 30 W 10 x 0,2 = 2 10 x 0,2 = 2
4 EU-Archive 4 x 2 = 8 4 x 2 = 8
Total 40 40
CI 3000 Store Computer with 6 MB of memory: 120 memory units
Number Memory units required
57 refrigeration points UA 300 / UA 300 D/L/V or
35 refrigeration points UA 300 E / UA 400 E
57 x 1,4 ~ 80
35 x 2,3 ~ 80
2 Compact-refrigeration points UA 30 Rx 2 x 1 = 2 2 x 1 = 2
4 refrigeration packs VS 3010 4 x 2,5 = 10 4 x 2,5 = 10
14 EU-Archive 14 x 2 = 28 14 x 2 = 28
Total 120 120
CI 3000 Store Computer with 16 MB of memory: 320 memory units
Number Memory units required
72 refrigeration points UA 300 / UA 300 D/L/V or
43 Memory units required UA 300 E / UA 400 E
72 x 1,4 ~ 100
43 x 2,3 ~ 100
9 refrigeration packs VS 3010 9 x 2,5 ~ 23 9 x 2,5 ~ 23
EU-Archive 94 x 2 = 188 94 x 2 = 188
3 Extension modules SIOX 3 x 0,33 = 1 3 x 0,33 = 1
Total 312 312
(The CI 3100 is only available with 6 and 16 MB memory expansions)