EasyManua.ls Logo

EDAN H50 - User Manual

EDAN H50
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
I

Table of Contents

Questions and Answers:

EDAN H50 Specifications

General IconGeneral
BrandEDAN
ModelH50
CategoryMeasuring Instruments
LanguageEnglish

Summary

Chapter 1 Safety Guidance

Intended Use and Indications

Specifies the intended use of the H50/H51 Hematology Analyzer for measuring blood cells and providing results.

Safety Warnings and Cautions

Provides critical warnings and cautions for safe operation, installation, and maintenance of the analyzer.

Symbols and Definitions

Lists and defines symbols used in the manual and on the analyzer for clear understanding.

Chapter 2 General Overview

General Introduction

Provides an overview of the H50/H51 Hematology Analyzer's capabilities and the parameters it determines.

Analyzer Main Parts Overview

Details the main components of the analyzer, including the front cover, fluidic part, and connection board.

Analyzer Configuration Options

Outlines the standard configuration and available options for the H50 and H51 Hematology Analyzers.

Chapter 3 Measurement Principle

WBC, RBC, PLT Measurement Principles

Explains the electrical impedance method used for counting White Blood Cells, Red Blood Cells, and Platelets.

Five-part Diff Measurement Principle

Describes the optical measurement principle for differentiating White Blood Cells into five parts.

HGB Measurement Principle

Details the spectrophotometric method used for Hemoglobin (HGB) measurement.

MCV and MPV Measurement

Explains how Mean Cell Volume (MCV) and Mean Platelet Volume (MPV) are measured based on histograms.

Calculated Parameters Equations

Provides the formulas used for calculating various parameters from measured values.

Chapter 4 Installation Guidance

Installation Environment Requirements

Specifies the environmental conditions required for proper installation and operation of the analyzer.

Unpacking and Inspection

Guides users through the process of unpacking the analyzer and performing initial inspections.

Analyzer Installation Procedures

Details the step-by-step procedures for installing the H50/H51 Hematology Analyzer.

User Login and Access

Explains how to log in to the analyzer system and the different access levels available.

Chapter 5 Software Introduction

Software Toolbar Overview

Introduces the toolbar elements and their functionalities within the analyzer's software interface.

Common Software Buttons

Describes the common buttons used throughout the software and their functions.

Software Screen Navigation

Explains how to navigate between different screens and sub-screens of the analyzer's software.

Chapter 6 Reagents Management

Reagent Management: Diluent, Lyse, Cleaner

Details the procedures for managing diluent, lyse, and cleaner reagents within the system.

Waste Management Procedures

Explains the methods for disposing of waste collected by the analyzer.

Chapter 7 Startup

Startup Cycle Description

Describes the startup cycle, its purpose for daily checks, and the process after login.

Chapter 8 QC

Quality Control Targets and Limits

Covers the management of QC lot information, targets, and limits for instrument control.

Performing Quality Control Tests

Explains the mandatory procedure for running QC tests to ensure instrument stability.

Chapter 9 Calibration

Analyzer Calibration Process

Details the process of calibrating the analyzer to maintain accuracy and precision.

Calibrator Information Management

Explains how to manage calibrator information, including lot, expiry, targets, and limits.

Chapter 10 Repeatability

Repeatability Testing Procedures

Guides users on performing repeatability tests to assess the consistency of measurement results.

Chapter 11 Sample Test

Sample Preparation Guidelines

Provides instructions on collecting and preparing human blood samples for analysis.

Running Sample Tests

Details the process of running sample tests, including sample information editing and test execution.

Viewing Test Results

Explains how to view test results in both table and detail modes.

Searching Test Results

Describes how to search for past test results based on date and time or SID.

Re-editing Patient Data

Guides users on how to re-edit patient information if errors are found.

Chapter 12 Flags

Results Flags Interpretation

Explains the meaning of various flags displayed behind test values and their interpretations.

System Alerts and Messages

Lists system alerts, their triggers, and detailed information provided in pop-up windows.

Morphologic Alarms Overview

Covers morphologic alarms related to cell characterization, including causes and detailed pop-up information.

Pathological Alarms Overview

Details pathological alarms for WBC, RBC, and PLT, including their triggers and conditions.

Chapter 13 Service

System Initialization Procedures

Explains the process of initializing the analyzer's mechanical systems.

Event Logs Management

Describes how to access and interpret the event logs, which record analyzer operations.

Error Logs Management

Details how to access and interpret error logs for troubleshooting.

Data Backup and Restore

Guides users on backing up and restoring analyzer data and settings.

System Settings Configuration

Covers various settings like lab parameters, units, printer, communication, and user management.

Troubleshooting Guide

Provides solutions for common problems encountered during analyzer operation, categorized by software and mechanical issues.

Analyzer Maintenance Procedures

Outlines the recommended maintenance schedules and procedures, including cleaning cycles.

Chapter 14 Logout and Shutdown

Logout Procedure

Explains how to log out of the analyzer system, returning to the login screen.

Analyzer Shutdown Procedure

Details the process for safely shutting down the analyzer, with an option for bleach cleaning.

Chapter 15 Warranty and Service

Product Warranty Information

Outlines the warranty terms and conditions for EDAN products.

Service and Support Contact

Provides contact information for technical support, maintenance inquiries, and malfunctions.

Appendix 1 Specifications

Environmental Requirements

Lists the environmental conditions for analyzer usage, transport, and storage.

Analyzer Technical Specifications

Provides details on the analyzer's size, weight, screen, and connection types.

Analytical Performance Specifications

Details the analyzer's sample volume, throughput, and power adapter specifications.

Power Adapter Specifications

Specifies the size, weight, input, and output power of the analyzer's adapter.

Appendix 2 Analytical Performance

Linear Range Specifications

Defines the linear ranges and limits for various parameters measured by the analyzer.

Background Requirements

Specifies the background or blank count requirements for key parameters.

Precision Specifications

Lists the precision specifications for different parameters within specified ranges.

Carry-over Specifications

Details the carry-over specifications for WBC, RBC, HGB, and PLT parameters.

Accuracy Specifications

Provides the accuracy specifications, including detection range and limit percentages for parameters.

Measurement Range Specifications

Lists the measurement ranges for all parameters in different units.

Appendix 4 EMC Information

Electromagnetic Emissions Declaration

Details the electromagnetic emissions compliance and guidance for the analyzer.

Electromagnetic Immunity Declaration

Provides the electromagnetic immunity compliance levels and guidance for the analyzer.

Appendix 3 Safety Specifications

Safety Compliance and Ranges

Summarizes safety compliance standards, temperature, humidity, pollution, and gas safety.

Appendix 5 Glossary

Glossary of Terms

Provides a list of abbreviations used in the manual and their full names.

Appendix 6 User Access

User Access Level Definitions

Details the access rights for Operator, Administrator, and Technician roles within the system.

Related product manuals