STP-iS1607 Series Turbomolecular Pump
MT-94E-001-C
Page 81
5
SERIAL COMMUNICATION PROTOCOL
5.3 Protocol specifications
5.3.1 General description
The STP serial communication protocol enables the SIM to receive the communication command
transmitted from the PC and sends a response following the communication command (Figure 42-1).
Each communication command from the PC transmits a text message (ASCII text) assigned to each
function (Figure 42-2). Communication commands include control commands (STP pump operation
commands, etc.) and query commands (read-out of STP pump operation mode, etc.).
1. Communication command
2. Response
Figure 42 - PC to SIM communication