STP-iS1607 Series Turbomolecular Pump
MT-94E-001-C
Page 32
3
INSTALLATION OF THE STP PUMP
Item
Description
Function
1
"POWER" LED
(Green LED) Illuminates when 200 to 240 Va.c. is input to
the connector X1 (Power ON state). Refer to Section 4.8,
"LED.
2
"FAILURE" LED
(Red/Orange LED) A failure of the STP pump is indicated by
the flashing pattern of the red LED. The flashing pattern
indicates the failure type. Refer to Section 7, "SAFETY
FUNCTIONS".
A warning of the STP pump is indicated by flashing of the
orange LED. The flashing pattern indicates the warning type.
Refer to Section 7.2, ""WARNING" function".
3
"ROTATION" LED
(Green/Orange LED) The rotational speed is indicated by the
flashing pattern of the LED (acceleration state: green,
deceleration state: orange). Refer to Section 4.8, "LED".
4
"STP-LINK" connector (X5)
For the communication cable of the STP-Link (optional
accessory) or the display unit iDT-001 or iDT-002 (optional
accessory). (X5: STP-LINK) These optional accessories can
operate the STP pump, confirm the operation state, or
change various settings.
5
"REMOTE" connector (X2)
For remote input/output signal in the parallel mode setting.
(X2: D-Sub25 pin) See Section 4.9, "Parallel port input/output
signal".
6
"COM1" connector (X3)
For RS232 and RS485 (common use) serial communication.
(X3: D-Sub9 pin).
For the user application. See Section 5, "SERIAL
COMMUNICATION PROTOCOL".
For the Profibus unit (optional accessory). Refer to the
Instruction Manual of the Profibus.
7
"Data" LED
(Green LED) Installed only when the Profibus (optional
accessory) is equipped. Profibus Device (STP pump) is in
data exchange as defined by the Profibus standard.
8
"Off-Line" LED
(Orange LED) Installed only when the Profibus (optional
accessory) is equipped. Profibus Device (STP pump) is not
in data exchange as defined by the Profibus standard.
Table 4 - Control unit front panel functions

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Edwards STP-iS1607 Series and is the answer not in the manual?

Edwards STP-iS1607 Series Specifications

General IconGeneral
BrandEdwards
ModelSTP-iS1607 Series
CategoryWater Pump
LanguageEnglish

Related product manuals