22│en Commissioning
NOTICE
Alternative method of terminating test mode: Test mode is also
terminated in the following cases:
□ If the finger scanner is not operated for around 1 minute
□ If the system is disconnected from the power supply
Using a code pad
Press < or > until tE is displayed
Press ✓. All of the relays switch
one after another for the defined
relay switching duration (default
setting: 3 s).
The
status
LEDs
light up
red.
1 point
flashes
on the
left.
The entire system has been tested. The system is in normal mode.
NOTICE
Alternative method of terminating test mode: Test mode is also
terminated in the following cases:
□ If the code pad is not operated for around 1 minute
□ If the system is disconnected from the power supply