40│en Usage of the finger scanner with the control panel menu
NOTICE
Only for ekey home control panel integra: This function is only
available for
ekey home control panel integra
.
You can set the configuration of the digital input as follows.
Request-to-exit button
The digital input functions by default as a request-to-exit button for relay
1. In this case, the relay switches for the defined switching duration or for
as long as the digital input is enabled (e.g., request-to-exit button,
permanent opening).
Feedback
The LEDs on the registration unit indicate the status of digital input for 30
seconds when an authorized finger is swiped over the sensor or when an
authorized user code is entered on the keypad. If digital input is enabled,
the function LEDs on the finger scanner and the status LEDs on the code
pad light up red. If digital input is disabled, the function LEDs on the
finger scanner and the status LEDs on the code pad light up green. If the
status of the digital input changes within 30 seconds, this change is also
signaled in the same way. This enables you to see that the intrusion alarm
system is still appropriately sensitive, for example.
Block for relay 1
Relay 1 can no longer be switched while digital input 1 is enabled. The
LEDs on the registration unit indicate the status of digital input 1 for 30
seconds when an authorized finger is swiped over the sensor or when an
authorized user code is entered on the keypad. If digital input 1 is
enabled, the function LEDs on the finger scanner and the status LEDs on
the code pad light up red. If digital input 1 is disabled, the function LEDs
on the finger scanner and the status LEDs on the code pad light up green.
If the status of digital input 1 changes within 30 seconds, this change is
also signaled in the same way. However, the relay does not switch
automatically when digital input 1 changes from enabled to disabled.