Technical Support - MDM
58/104
599 77 39-16 Rev. 00
A
larm Description Possible faul
t
Machine status/action Rese
t
E52
No signal from motor tachometric
generator
Wiring faulty; Motor faulty; Inverter board faulty.
Cycle stops with door locked
(after 5 attempts)
ON/OFF
RESET
E53
Faulty sensing by motor TRIAC Main circuit board faulty. Cycle blocked RESET
E54
Motor relay contacts sticking Current leakage from motor or from wiring; Main PCB faulty.
Cycle blocked
(after 5 attempts)
RESET
E57
Inverter is drawing too much current
(>15°)
Wiring faulty on inverter for motor; Inverter PCB faulty; Motor faulty.
Cycle stops with door locked
(after 5 attempts)
ON/OFF
RESET
E58
Inverter is drawing too much current
(>4.)
Motor malfunction (overload); Wiring faulty on inverter faulty;
Motor faulty; Inverter PCB faulty.
Cycle stops with door locked
(after 5 attempts)
ON/OFF
RESET
E59
No rotation of the motor Wiring faulty on inverter for motor; Inverter PCB faulty; Motor faulty.
Cycle stops with door locked
(after 5 attempts)
ON/OFF
RESET
E5A
Overheating on heat dissipator for
Inverter
Overheating caused by continuous operation or ambient conditions
(let appliance cool down); Inverter PCB faulty;
NTC open (on the Inverter PCB).
Cycle stops with door locked
(after 5 attempts)
ON/OFF
RESET
E5C
Input voltage is too high
Input voltage is too high (measure the grid voltage);
Inverter PCB faulty.
Cycle stops with door locked
(after 5 attempts)
ON/OFF
RESET
E5d
Data transfer error between Inverter
and main PCB
Line interference; Wiring faulty; Faulty main PCB or inverter PCB. ----------------
ON/OFF
RESET
E5E
Communication error between
Inverter and main PCB
Faulty wiring between main PCB and inverter PCB;
Inverter PCB faulty; Main PCB faulty.
Cycle blocked
(after 5 attempts)
ON/OFF
RESET
E5F
Inverter PCB fails to start the motor Wiring faulty; Inverter PCB faulty; Main PCB faulty.
Cycle stops with door open
(after 5 attempts)
ON/OFF
RESET
E5H
Input voltage is lower than 175 V Wiring faulty; Inverter PCB faulty.
Cycle stops with door locked
(after 5 attempts)
ON/OFF
RESET
E61
Insufficient heating during washing
Wiring faulty; NTC probe for wash cycle faulty;
Heating element faulty; Main PCB faulty.
The heating phase is skipped START/RESET
E62
Overheating during washing
(temperature higher than 88 °C for
more than 5 min.)
Wiring faulty; NTC probe for wash cycle faulty;
Heating element faulty; Main PCB faulty.
Safety drain cycle
Cycle stops with door open
RESET
E66
Heating element power relay faulty
(inconsistency between sensing and
relay status)
Earth leakage between heating element and earth;
Main PCB faulty.
Safety water fill
Cycle stops with door closed
ON/OFF
RESET
E68
Earth leakage Earth leakage between heating element and earth. The heating phase is skipped START/RESET
E69
Heating element interrupted
Wiring faulty; Heating element for washing interrupted (thermal fuse
open); Main PCB faulty.
----------------
START
ON/OFF
RESET
E6
A
Heating relay sensing faulty Main circuit board faulty. Cycle stops with door locked RESET
E6H
Heating element power relay faulty
(inconsistency between sensing and
relay status)
Wiring faulty; Earth leakage between heating element and earth;
Main PCB faulty.
Safety water fill
Cycle stops with door closed
ON/OFF
RESET
E71
NTC probe for wash cycle faulty
(short-circuited or open)
Wiring faulty; NTC probe for wash cycle faulty;
Main circuit board faulty.
The heating phase is skipped START/RESET