599 77 39-16 Rev. 00
A
larm Description Possible faul
t
Machine status/action Rese
t
E74
NTC probe for wash cycle
improperly positioned
Wiring faulty; NTC probe for wash cycle improperly positioned;
NTC probe faulty; Main PCB faulty.
The heating phase is skipped RESET
E84
Recirculation pump TRIAC
“sensing” circuit faulty
Main circuit board faulty.
Safety drain cycle - Cycle stops
with door open
RESET
E85
Circulation pump TRIAC switch
faulty
Wiring faulty; Recirculation pump faulty; Main PCB faulty.
Safety drain cycle - Cycle stops
with door open
RESET
E87
Display board microprocessor faulty If this continues, replace the display board.
No action to be taken
START
ON/OFF
RESET
E91
Communication error between
main PCB and display
Wiring faulty; Control/display circuit board faulty;
Inverter Board faulty, Main circuit board faulty.
---------------- RESET
E92
Communication inconsistency
between main PCB and display
(incompatible versions)
Incorrect control/display PCB;
Incorrect PCB (does not correspond to the model).
Cycle blocked ON/OFF
E93
Appliance configuration error Main PCB faulty (incorrect configuration data). Cycle blocked ON/OFF
E94
Incorrect configuration of
washing cycle
Main PCB faulty (incorrect configuration data). Cycle blocked ON/OFF
E97
Inconsistency between programme
selector and cycle configuration
Main PCB faulty (incorrect configuration data). Cycle blocked RESET
E98
Communication error between
main PCB - Inverter
Incompatibility between main PCB and Inverter. Cycle blocked ON/OFF
E9C
Display board configuration error Display board faulty. ----------------
START
ON/OFF
RESET
E9E
Display board sensor/touch key
faulty
Display board faulty. ---------------- ON/OFF
EC1
Electronically controlled valve
blocked with operating flowmeter
Faulty wiring; Faulty/blocked solenoid; PCB faulty.
Cycle stops with door locked
Drain pump continues to operate
(5 min. on, then 5 min. off. etc.)
RESET
EC4
AGS current sensor faulty Main board faulty.
Spin speed reduced to safety speed
of 150 rpm
RESET
EF1
Drain filter clogged
(drain phase too long)
Drain filter clogged/dirty;
Drain hose blocked/kinked/too high.
Warning displayed at the end of cycle START/RESET
EF2
Overdosing of detergen
t
(too much foam during drain phases)
Excessive detergent dosing; Drain hose kinked/blocked;
Drain filter clogged/dirty.
Warning displayed after 5 attempts
or by the specific LED
RESET
EF3
Aqua control system intervention
Water leaks onto base frame; Aqua control system faulty;
Drain pump coil overheating/broken.
Appliance drain ON/OFF RESET
EF4
Water fill pressure too low, no signal
from flowmeter and electronically
controlled valve is open
Tap closed; Water fill pressure too low. ---------------- RESET
EF
5
Unbalanced load Final spin phases skipped. ---------------- START/RESET