EF6
Reset If it continues, replace the main board. No action to be taken ----------------
EH1
Appliance power supply frequency
out of limits
Problem with the power supply network (incorrect/disturbed);
Main PCB faulty.
Wait for nominal frequency conditions ON/OFF
EH2
Supply voltage too high
Problem with the power supply network (incorrect/disturbed);
Main PCB faulty.
Wait for nominal voltage conditions ON/OFF
EH3
Supply voltage too low
Problem with the power supply network (incorrect/disturbed);
Main PCB faulty.
Wait for nominal voltage conditions ON/OFF
EHE
Inconsistency between FCV relay
(in the main board) and safety
“sensing” circuit
Faulty wiring; Main circuit board faulty.
Safety drain cycle
Cycle stops with door open
RESET
EHF
Safety sensing circuit faulty (wrong
input voltage to microprocessor)
Main circuit board faulty.
Safety drain cycle
Cycle stops with door open
RESET