EasyManua.ls Logo

Emerson DSM314 - Page 111

Emerson DSM314
519 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User Manual Chapter 4
GFK-1742F Jan 2020
Configuration 100
Configuration
Parameter
Description
Values
Default
Units
Reference
Section
12 = 4 Axis
Number of Axes
setting
Axis 1 Mode
Axis 1 Control Mode
Analog Servo
Digital Servo
Analog Servo
N/A
1.03
Axis 2 Mode
Axis 2 Control Mode
Analog Servo
Digital Servo
Auxiliary Axis
Analog Servo
N/A
1.03
Axis 3 Mode
Axis 3 Control Mode
Analog Servo
Auxiliary Axis
Auxiliary Axis
N/A
1.03
Axis 4 Mode
Axis 4 Control Mode
Disabled
Analog Servo
Auxiliary Axis
Disabled
N/A
1.03
Local Logic
Mode
The Local Logic
Engine mode
Disabled
Enabled
Disabled
N/A
1.04
Total Encoder
Power
Encoder power
requirements
RX3i: 0.000 through
0.500
90-30: 0 through 2.5
0
RX3i: Amps
90-30: Watts
1.05
Motion Program
Block Name
The motion program
name to execute on the
module
Name must be 20
characters or less
and begin with a
letter or underscore
(_). Only
alphanumeric
characters and non-
consecutive
underscores are
allowed.
<blank>
N/A
1.06
Local Logic
Block Name
The local logic program
name to execute on the
module
<blank>
N/A
1.07
CAM Block
Name
The CAM block name to
execute on the module
<blank>
N/A
1.08
I/O Scan Set
(RX3i only)
The scan set (as defined in
the CPU's Scan Sets tab)
to be assigned to this
module.
1 through 32
1
N/A
1.09

Table of Contents

Related product manuals