User Manual Chapter 15
GFK-1742F Jan 2020
Using the Electronic CAM Feature 350
Figure 164: Inserting a Point in the Profile Editor Window
Since the Slave Position end point is the same value (0) as the initial Slave Position point, this
CAM meets the requirements for a Linear Cyclic CAM. (For more information on the different
CAM types, refer to “CAM Types” on page 326.) Note that the CAM Editor has several
“Smart” edit fields that will ONLY display the choices that are valid for a given data set. For
example, since a requirement for a Linear Cyclic CAM is that the Slave Position start point
and Slave Position end point are the same, the editor only allows the Linear Cyclic CAM
choice if these criteria is met.
Next, insert a new point into the profile and then edit the point. The point can be edited
either in the profile table or graphically on the plot. Insert the point as shown above and in
Figures 165 and 166 by right clicking the point below the insertion position and selecting
Insert Point from the menu. Then change the default values to 2500 for the Master and
10000 for the Slave.
Figure 165: CAM Profile Table Data