User Manual Chapter 15
GFK-1742F Jan 2020
Using the Electronic CAM Feature 356
Step 10: Set up Hardware Configuration in Logic Developer
Once a successful syntax check is completed for the local logic and motion programs, you
need to set up the hardware configuration that will allow the example program to be
downloaded to the DSM314 module. Most users will first set up their hardware
configuration and then generate the programming statements. However, because this
example is intended to illustrate the CAM feature the order is reversed to better illustrate
the link the CAM block name and the DSM314 hardware configuration.
Configure the power supply, CPU, and DSM314 module that are appropriate for your
installation. For general information on hardware configuration, refer to chapter 4.
Change the following Settings tab parameters to the values shown. (Axis 1 and Axis 2 modes
are set to digital servo because this example uses the
β
is 0.5 digital servo.)
Axis 1 Mode
Digital Servo
Axis 2 Mode
Digital Servo
Local Logic Block Name
CamExLLPgm
Cam Block Name
CamBlk
Local Logic Mode
Enabled
The resulting Settings tab will be as shown in Figure 170 .
Note: This example uses only one DSM314.The DSM314 executes the files (CAM, Local Logic, and Motion
Program) pointed to by the configuration. Multiple DSM314 modules can run the same Local
Logic program, motion programs, or CAM Blocks. This allows you to have one source file for
multiple DSM314 modules. Note that this does not prevent DSM314s from executing different
programs.
Figure 170: Hardware Configuration 90-30 rack DSM314 Settings Tab