DCM00044 REV. 14 37
4.4 Installation Requirements
4.4.1 Location
The actuator may be installed in a variety of positions. The Ultraweld L20 is often
manually operated using a foot switch, and so it can be installed at a safe and comfortable
workbench height (approximately 30-36 inches) with the operator sitting or standing in
front of the system. The power supply may be located up to 20 feet away from the
Ultraweld L20 Actuator.
The power supply must be accessible for user parameter changes and settings, and must
be placed in a horizontal orientation. The power supply should be positioned so it does not
draw in dust, dirt or material via its rear fans. Refer to the illustrations on the pages that
follow for a dimensional drawing of each component.
4.4.2 Environmental Specifications
Table 4.3 Environmental Specifications
Environmental concern Acceptable Range
Humidity 30% to 90%, non-condensing
Ambient Operating Temperature +5° C to +50° C (41° F to 122° F)
IP Rating 2X
Operating Altitude 1000 m (3280 ft)