DCM00002 REV. 16 43
5.4 Weld Settings Screen
Figure 5.3 Weld Settings screen
Weld Settings Screen
From this screen you may change individual weld parameters which are the basic
elements required to make a weld.
Press one of the following options for this screen:
ENERGY
To change the amount of energy (joules) delivered for each weld. See 5.35 Typical Keypad
Entry Screen.
WELD PRESSURE
To change the clamping pressure delivered by the actuator while the weld is taking place.
See 5.35 Typical Keypad Entry Screen.
BATCH
To set a batch count quantity which will display from the Run Screen in data mode. See
5.35 Typical Keypad Entry Screen.
TRIGGER PRESSURE
To change the pressure used to engage the knurl pattern into the component parts prior to
initiation of ultrasonic energy. See 5.35 Typical Keypad Entry Screen.
TIME
To change the time duration of ultrasonic energy applied for each weld cycle. See 5.35
Typical Keypad Entry Screen.
Available only when Weld Mode is set to Time. See 5.5 Weld Mode Screen.
AMPLITUDE
To change amplitude which is measured in microns. If an amplitude stepping mode has
been selected on the Weld Mode screen, you will be able to enter Amp-A, Amp-B, and a
Step Point. Amplitude is the displacement of mechanical motion of the horn. See 5.35
Typical Keypad Entry Screen.