Installation Proline Promag 53 MODBUS RS485
34 Endress+Hauser
Welding the transmitter into the pipe (weld nipple)
"
Caution!
Risk of electronics being destroyed. Please ensure that the welding system is not grounded via the
sensor or transmitter.
1. Secure the sensor using several welding points in the piping. A welding jig suitable for this
purpose can be ordered separately as an accessory ä 94.
2. Loosen the screws at the process connection flange, and remove the sensor incl. seal from the
piping.
3. Weld the process connection into the pipe.
4. Mount the sensor back into the pipe. When doing so, make sure that the seal is clean and
positioned correctly.
!
Note!
If the welding is done properly with thin-walled food pipes, the seal will not be damaged by heat
even when mounted. Nonetheless, it is recommended that you dismantle the sensor and seal.
For dismantling purposes, it must be possible to open the piping a total of approx. 8 mm.
Cleaning using pigs
When cleaning using pigs, please note the internal diameters of the measuring tube and the process
connection. All the dimensions and lengths of the sensor and transmitter are provided in the
separate documentation "Technical Information" ä 134.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Endress+Hauser MODBUS RS485 and is the answer not in the manual?

Endress+Hauser MODBUS RS485 Specifications

General IconGeneral
BrandEndress+Hauser
ModelMODBUS RS485
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals