Proline Prowirl F 200 PROFIBUS PA Commissioning
Endress+Hauser 121
You can do so using the Configuration management parameter and the related options
found in the Configuration backup display submenu.
Navigation
"Setup" menu → Advanced setup → Configuration backup display
Configuration backup display
Operating time
Last backup
Configuration management
Comparison result
Parameter overview with brief description
Parameter Prerequisite Description User interface / 
Selection
Factory setting
Operating time Indicates how long the device
has been in operation.
Days (d), hours (h),
minutes (m) and
seconds (s)
Last backup A local display is provided. Indicates when the last data
backup was saved to the
display module.
Days (d), hours (h),
minutes (m) and
seconds (s)
Configuration management A local display is provided. Select action for managing the
device data in the display
module.
Cancel
Execute backup
Restore
Duplicate
Compare
Clear backup data
Cancel
Comparison result A local display is provided. Comparison between present
device data and display
backup.
Settings identical
Settings not
identical
No backup
available
Backup settings
corrupt
Check not done
Dataset
incompatible
Check not done
10.7.1 Function scope of the "Configuration management" parameter
Options Description
Execute backup The current device configuration is backed up from the integrated HistoROM to the
device's display module. The backup copy includes the transmitter data of the
device.
Restore The last backup copy of the device configuration is restored from the display
module to the device's integrated HistoROM. The backup copy includes the
transmitter data of the device.
Duplicate The transmitter configuration from another device is duplicated to the device using
the display module.