Commissioning Proline Prowirl F 200 PROFIBUS PA
76 Endress+Hauser
10.5.2 Selecting and setting the medium
The Medium selection wizard guides you systematically through all the parameters that
have to be configured for selecting and setting the medium.
Navigation
"Setup" menu → Medium selection
Structure of the wizard
End of wizard
Select
medium
Liquid
Gas
Steam
Select
gas type
Select
liquid type
Air
Natural
gas
Enthalpy calc.
Density calc.
User-spec.
gas
Gas
mixture
Single
gas
Water
LPG
User-spec.
liquid
Fixed process pressure
Enthalpy type
A0020776-EN
 22 "Medium selection" wizard in the "Setup" menu
Parameter overview with brief description
Parameter Prerequisite Description Selection / User
entry
Factory setting
Select medium Select medium type. Gas
Liquid
Steam
Steam
Select gas type The following conditions are
met:
Order code
"Sensor version", option
"Mass flow"
"Application package",
option "Air + Industrial
gases" or option "Natural
gas"
The Gas option is selected in
the Select medium
parameter.
Select measured gas type. Single gas
Gas mixture
Air
Natural gas
User-specific gas
User-specific gas