EasyManua.ls Logo

Endress+Hauser Proline 200 - Page 93

Endress+Hauser Proline 200
218 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Proline Prowirl F 200 PROFIBUS PA Commissioning
Endress+Hauser 93
Parameter overview with brief description
Parameter Prerequisite Description Selection / User
entry
Factory setting
Gas type The following conditions are
met:
• In the Select medium
parameter, the Gas option is
selected.
• In the Select gas type
parameter, the Single gas
option is selected.
Select measured gas type. • Hydrogen H2
• Helium He
• Neon Ne
• Argon Ar
• Krypton Kr
• Xenon Xe
• Nitrogen N2
• Oxygen O2
• Chlorine Cl2
• Ammonia NH3
• Carbon monoxide
CO
• Carbon dioxide
CO2
• Sulfur dioxide SO2
• Hydrogen sulfide
H2S
• Hydrogen chloride
HCl
• Methane CH4
• Ethane C2H6
• Propane C3H8
• Butane C4H10
• Ethylene C2H4
• Vinyl Chloride
C2H3Cl
Methane CH4
Gas mixture The following conditions are
met:
• In the Select medium
parameter, the Gas option is
selected.
• In the Select gas type
parameter, the Gas mixture
option is selected.
Select measured gas mixture. • Hydrogen H2
• Helium He
• Neon Ne
• Argon Ar
• Krypton Kr
• Xenon Xe
• Nitrogen N2
• Oxygen O2
• Chlorine Cl2
• Ammonia NH3
• Carbon monoxide
CO
• Carbon dioxide
CO2
• Sulfur dioxide SO2
• Hydrogen sulfide
H2S
• Hydrogen chloride
HCl
• Methane CH4
• Ethane C2H6
• Propane C3H8
• Butane C4H10
• Ethylene C2H4
• Vinyl Chloride
C2H3Cl
• Others
Methane CH4

Table of Contents