Proline Promag H 300 PROFINET Operation
Endress+Hauser 131
Parameter overview with brief description
Parameter Prerequisite Description Selection / User
entry / User
interface
Factory setting
Assign process variable – Select process variable for
totalizer.
• Volume flow
• Mass flow
• Corrected volume
flow
• Total mass flow
• Condensate mass
flow
• Energy flow
• Heat flow
difference
Volume flow
Totalizer value 1 to n In the Assign process variable
parameter one of the following
options is selected:
• Volume flow
• Mass flow
• Corrected volume flow
• Total mass flow
• Condensate mass flow
• Energy flow
• Heat flow difference
Displays the current totalizer
counter value.
Signed floating-point
number
0 m³
Totalizer status 1 to n – Displays the current totalizer
status.
• Good
• Uncertain
• Bad
–
Totalizer status (Hex) 1 to n In Target mode parameter,
the Auto option is selected.
Displays the current status
value (hex) of the totalizer.
0 to 0xFF –
11.4.3 "Input values" submenu
The Input values submenu guides you systematically to the individual input values.
Navigation
"Diagnostics" menu → Measured values → Input values
‣
Input values
‣
Current input 1 to n
→ 131
‣
Status input 1 to n
→ 132
Input values of current input
The Current input 1 to n submenu contains all the parameters needed to display the
current measured values for every current input.