Proline Promag H 300 PROFINET Technical data
Endress+Hauser 199
Vibration- and shock-
resistance
Vibration sinusoidal, in accordance with IEC 60068-2-6
2 to 8.4 Hz, 3.5 mm peak
8.4 to 2 000 Hz, 1 g peak
Vibration broad-band random, according to IEC 60068-2-64
10 to 200 Hz, 0.003 g
2
/Hz
200 to 2 000 Hz, 0.001 g
2
/Hz
Total: 1.54 g rms
Shock half-sine, according to IEC 60068-2-27
6 ms 30 g
Rough handling shocks according to IEC 60068-2-31
Mechanical load Protect the transmitter housing against mechanical effects, such as shock or impact.
Never use the transmitter housing as a ladder or climbing aid.
Interior cleaning Cleaning in place (CIP)
Sterilization in place (SIP)
Electromagnetic
compatibility (EMC)
As per IEC/EN 61326 and NAMUR Recommendation 21 (NE 21)
Details are provided in the Declaration of Conformity.
16.9 Process
Medium temperature range –20 to +150 °C (–4 to +302 °F)
0
0
0
0
-20-40
-40
20
20
40
100
60
140
[°F] [°C]
40 60 80 100
100
120 140 160
200 300
180
360
-20
-40
-40
T
A
T
F
[°F]
[°C]
A0027450
T
A
Ambient temperature range
T
F
Fluid temperature
The permitted fluid temperature in custody transfer is 0 to +50 °C (+32 to +122 °F).