Installation Proline Promag H 300 PROFINET
24 Endress+Hauser
Vibrations
L > 10 m (33 ft)
A0029004
 5 Measures to prevent vibration of the device
In the event of very strong vibrations, the pipe and sensor must be supported and fixed.
Information on the shock resistance of the measuring system
Information on the vibration resistance of the measuring system
Adapters
Suitable adapters to DIN EN 545 (double-flange reducers) can be used to install the sensor
in larger-diameter pipes. The resultant increase in the rate of flow improves measuring
accuracy with very slow-moving fluids. The nomogram shown here can be used to
calculate the pressure loss caused by reducers and expanders.
The nomogram only applies to liquids with a viscosity similar to that of water.
If the medium has a high viscosity, a larger measuring tube diameter can be
considered in order to reduce pressure loss.
1. Calculate the ratio of the diameters d/D.
2. From the nomogram read off the pressure loss as a function of flow velocity
(downstream from the reduction) and the d/D ratio.
100
10
0.5
d / D
[mbar]
0.6 0.7 0.8 0.9
1 m/s
2 m/s
3 m/s
4 m/s
5 m/s
6 m/s
7 m/s
8 m/s
1
D
d
max. 8°
A0029002