Proline Promag W 800 Technical data
Endress+Hauser 109
Liner: PTFE
Nominal diameter Limit values for absolute pressure in [mbar] ([psi]) for medium temperatures:
[mm] [in] +25 °C (+77 °F) +70 °C (+158 °F)
25 1 0 (0) 0 (0)
40 2 0 (0) 0 (0)
50 2 0 (0) 0 (0)
65 2 ½ 0 (0) 40 (0.58)
80 3 0 (0) 40 (0.58)
100 4 0 (0) 135 (2.0)
125 5 135 (2.0) 240 (3.5)
150 6 135 (2.0) 240 (3.5)
200 8 200 (2.9) 290 (4.2)
250 10 330 (4.8) 400 (5.8)
300 12 400 (5.8) 500 (7.3)
Flow limit The diameter of the pipe and the flow rate determine the nominal diameter of the sensor.
The optimum velocity of flow is between 2 to 3 m/s (6.56 to 9.84 ft/s).
A necessary increase in the flow velocity can be achieved by reducing the sensor
nominal diameter.
For custody transfer, the applicable approval determines the permitted measuring
range.
Pressure loss • No pressure loss occurs if the sensor is installed in a pipe with the same nominal
diameter.
• Pressure losses for configurations incorporating adapters according to DIN EN 545
→ 29
DN80
(3")
DN65
(2½")
DN50
(2")
500
450
400
350
300
250
200
150
100
50
0
0 10 20 30 40 50 60 70 80 90 100 110 120
[mbar]
[m /h]³
0 100 200 300 400 50050 150 250 350 450
[gal/min]
7
[psi]
0
1
2
3
4
5
6
A0032667-EN
17 Pressure loss DN 50 to 80 (2 to 3") for order code for "Design", option C "Fixed flange, constricted
measuring tube", 0 x DN inlet/outlet runs"