What to do if Endress+Hauser Proline Promag W 800 shows correct value on display but signal output is incorrect?
D
Daniel CrawfordAug 27, 2025
If your Endress+Hauser Measuring Instruments device shows the correct value on the local display but the signal output is incorrect (though within the valid range), it is likely due to a configuration error. Check and correct the parameter configuration.
M
Mark PittsAug 27, 2025
Why is my Endress+Hauser Measuring Instruments device not responding via SmartBlue App?
J
John SmithAug 27, 2025
If your Endress+Hauser Measuring Instruments device is not responding via the SmartBlue App, it may be due to the absence of a Bluetooth connection or because the device is already connected to another smartphone or tablet. Ensure that the Bluetooth function is enabled on your smartphone or tablet.
M
michael19Aug 25, 2025
Why is my Endress+Hauser Proline Promag W 800 Measuring Instruments measuring incorrectly?
W
wallacekennethAug 26, 2025
If your Endress+Hauser Measuring Instruments device is measuring incorrectly, it could be due to a configuration error or operation outside of the specified application limits. To resolve this:
1. Check and correct the parameter configuration.
2. Observe the limit values specified in the Technical Data.
A
Aaron OliverAug 23, 2025
How to fix write access to parameter not possible on Endress+Hauser Proline Promag W 800?
S
Steven CastroAug 25, 2025
If write access to a parameter is not possible, it may be because hardware write protection is enabled. Check the user role, enter the correct customer-specific access code, or verify the hardware write protection via DIP switch.
Endress+Hauser Proline Promag W 800 Specifications
General
Device Type
Electromagnetic Flowmeter
Measurement Principle
Faraday's law of electromagnetic induction
Housing Material
Aluminum, stainless steel
Pressure Rating
Up to 40 bar
Output Signal
4 to 20 mA HART, Modbus RS485, PROFIBUS DP, PROFINET