Command Line Interface
4-82
4
Command Usage
• If the power demand from devices connected to the V2H124-24P exceeds
the power budget setting, the switch uses port power priority settings to
control the supplied power. For example:
- A device connected to a low-priority port that causes the switch to exceed
its budget is not supplied power.
- A device connected to a critical or high-priority port that causes the switch
to exceed its budget is supplied power, but the switch drops power to one
or more lower-priority ports.
• Power is dropped from low-priority ports in sequence starting from port
number 1.
Example
Related Commands
power mainpower maximum allocation (4-79)
show power inline status
Use this command to display the current power status for all ports or for specific
ports.
Syntax
show power inline status [interface]
interface
- ethernet
- unit - This is device 1.
- port - Physical port number on the switch (Range: 1-26).
Command Mode
Privileged Exec
Command Usage
This command displays the following parameters:
• Admin – The power mode set on the port (configurable, see
power inline 4-80.)
• Oper – The current operating power status (displays on or off).
• Power(mWatt) – The available power budget for the port (configurable, see
power inline maximum allocation
4-80.)
• Power(used) – The current power consumption on the port in milliwatts.
Console(config)#interface ethernet 1/1
Console(config-if)#power inline priority 2
Console(config-if)#

Table of Contents

Other manuals for Enterasys Matrix-V V2H124-24

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys Matrix-V V2H124-24 and is the answer not in the manual?

Enterasys Matrix-V V2H124-24 Specifications

General IconGeneral
BrandEnterasys
ModelMatrix-V V2H124-24
CategorySwitch
LanguageEnglish

Related product manuals