Basic Configuration
3-25
3
Telnet Settings
You can access the onboard configuration program over the network using Telnet
(i.e., a virtual terminal). Management access via Telnet can be enabled/disabled and
other various parameters set, including the TCP port number, timeouts, and a
password. These parameters can be configured via the Web or CLI interface.
Command Attributes
• Telnet Status – Enables or disables Telnet access to the switch.
Default: Enabled)
• Telnet Port Number – Sets the TCP port number for Telnet on the switch.
(Default: 23)
• Login Timeout – Sets the interval that the system waits for a user to log into the
CLI. If a login attempt is not detected within the timeout interval, the connection is
terminated for the session. (Range: 0 - 300 seconds; Default: 300 seconds)
• Exec Timeout – Sets the interval that the system waits until user input is detected.
If user input is not detected within the timeout interval, the current session is
terminated. (Range: 0 - 65535 seconds; Default: 600 seconds)
• Password Threshold – Sets the password intrusion threshold, which limits the
number of failed logon attempts. When the logon attempt threshold is reached, the
system interface becomes silent for a specified amount of time (set by the Silent
Time parameter) before allowing the next logon attempt. (Range: 0-120; Default: 3
attempts)
• Password* – Specifies a password for the line connection. When a connection is
started on a line with password protection, the system prompts for the password.
If you enter the correct password, the system shows a prompt. (Default: No
password)
• Login* – Enables password checking at login. You can select authentication by a
single global password as configured for the Password parameter, or by
passwords set up for specific user-name accounts (the default).
* CLI only.
Web – Click System, Line, Telnet. Specify the connection parameters for Telnet
access, then click Apply.
Figure 3-14. Telnet Settings

Table of Contents

Other manuals for Enterasys Matrix-V V2H124-24

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys Matrix-V V2H124-24 and is the answer not in the manual?

Enterasys Matrix-V V2H124-24 Specifications

General IconGeneral
BrandEnterasys
ModelMatrix-V V2H124-24
CategorySwitch
LanguageEnglish

Related product manuals