EPSON Stylus COLOR 440, 640, and 740 Chapter 5 Adjustments
132
6.
After
ou input the head ID, it takes about 5 seconds to store it in the
EEPROM. After the value has been stored, the confirmation
screen shown below appears:
Figure 5-24. Head Voltage ID Confirmation Screen
7.
Press Esc once. The Head Volta
e ID Menu screen reappears
Fi
ure 5-22
.
8.
Select
Check present data
. The screen below appears, enablin
ou to check the value
ou
ust entered.
Figure 5-25. Checking the Head Voltage ID
M S-D O S P rom pt-SC 640
W riting to EEPRO M now.
M S-D O S P rom pt-SC 640
Esc: P revious
This process takes about
5 seconds.
18218 has been written in EEPRO M as the
HEAD ACTUATOR VO LTAG E ID.
R eading the present head voltage value.
HEAD VO LTAG E ID = 18218
Esc: Previous